Testing In-Wall Compressive Strength Agawam MA

There are four methods in Agawam for determining the compressive strength of existing walls. The first is to remove a section from the wall and send it for laboratory testing per ASTM E 447.

Stephen A. Roberts Landscape Architecture and Construction
413-214-6990
1160 Bay Street
Springfield, MA
Kentucky Blue Landscaping LLC
(860) 242-4477
124 W. Dudley Town Road
Bloomfield, CT
Plantations, Inc.
(860) 242-2554
102 Old Poquonock Road
Bloomfield, CT
Frank Fragale & Sons Landscaping Corporation
508-358-5335
105 Boston Post Road
Wayland, MA
Gregory Lombardi Design
561.228.1467
2235 Massachusetts Ave
Cambridge, MA
The Green Machine, Inc.
(860) 243-9000
P. O. Box 336
Bloomfield, CT
Lee's Landscaping, LLC
(860) 242-9888
4 Adams Road
Bloomfield, CT
Walsh Landscaping, Inc.
781-438-0706
49 Franklin Street
Stoneham, MA
The Green Boys Landscapes
774-230-2940
56 Allen Rd
Sturbridge, MA
Viburnum Landscape Design
508 388 7788
67 Trotting Park Road
East Falmouth, MA
Data Provided by:
  
Provided By:

Testing In-Wall Compressive Strength

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 1992

Our firm is adding a partial second story to an old warehouse to convert it to an office building. The foundation and soil conditions make the project possible, but how can I determine the compressive strength of the existing masonry? How many areas should I test? What methods are most cost effective?
I know four methods for determining the compressive strength of existing walls. The first is to remove a section from the wall and send it for laboratory testing per ASTM E 447. There are some problems with this approach, however. Physically removing samples from the wall affects its appearance. Depending on the building's age, matching the color and texture of the masonry units removed may be nearly impossible. Also, samples may be damaged during removal or shipping, especially if the wall has multiple wythes. A second method is to make two vertical cuts entirely through the wall thickness and remove some of the masonry between these cuts. An in-place compression test can be performed using a hydraulic ram. As with the previous test method, the wall will be damaged by this testing and it may be difficult to perform in multi-wythe systems. Because the test is performed in place, however, samples will not be disturbed in shipping. The third method involves removing masonry units and samples of the mortar and estimating the compressive strength. The masonry units are tested in accordance with ASTM C 6...